Electrochemical O3 Ozone Sensor Module FS01101
- O3 detection sensor
- Electro-chemical sensor
- Outstanding anti-interference
- Temperature compensation
- Reliable service for sustainable cooperation
Electrochemical O3 Ozone Sensor Module FS01101 Introduction
FS01101 is a fuel cell type electrochemical sensor that works by the oxidation and reduction reactions on the working electrode and counter electrode, releasing charges to form a current. The magnitude of the current generated is proportional to the concentration of ozone and follows Faraday’s law. By testing the magnitude of the current, the ozone concentration can be determined. It uses a high-stability gas sensor and a high-performance microprocessor with UART output for easy use. The module adopts precise automatic calibration and detection equipment, reducing human interference and ensuring the accuracy and consistency of data during large-scale production. This ozone sensor is very suitable for portable product applications, with a small and convenient design for integration.
Electrochemical O3 Ozone Sensor Module FS01101 Features
1.Detection range
Default: 0~10PPM (Extendable)
2.High accuracy, high consistency, high solution
Data detection accuracy: ≤2% reading
Minimum solution: 0.001 ppm
3.Long service life:
The lifetime is up to 2 years (in the air)
4.High detection frequency
The data updates once per second by default.
Application
1.Disinfection equipment, electrical safety equipment
2.Smart Home Devices, Air Purifiers
3.Hospitals, hotels, schools and other public places
4.Portable instrumentation, air quality monitoring equipment
Specifications
Parameter type | Parameter index | |
Detection Type | O3 Gas | |
Detection Principle | Electro-chemical | |
Detection Range | 0~10PPM (Extendable) | |
Interference Gas | NO2、Cl2 | |
Detection Accuracy | Min Solution | 0.001ppm |
Data Accuracy | ≤2% Reading | |
Operation Voltage | DC 3.7V~6.0V | |
Operation Current | ≤10mA (@5V power supply) | |
Warm-up Time | 3 min | |
Detection Frequency | The data is updated once per second (Default) | |
Output Methods | UART (3.3V_TTL Voltage level) | |
Service Life | 2 Years (in the air) | |
Reference Dimension | 19.3×17.2×5.4 mm | |
Operation Temperature | -10℃~ 50℃ | |
Operation Humidity | 0~95%RH (Non-Condensation) | |
Storage Temperature | -20℃~ 60℃ | |
Storage Humidity | 0~99%RH (Non-Condensation) |