Air Quality Monitor FS00802C
- Multi-in-one air quality monitor
- Using independent sensor probe
- Support RS485、4G、bluetooth、WIFI、Analog signal、Lora output methods
- Customized according to customer requirements
- Wall Mounted and ceiling mounted
- Reliable service for sustainable cooperation
Air Quality Monitor FS00802C Introduction
FS00802C is a multi-parameter air quality sensor that can detect and output real-time data on multiple air quality parameters, including PM2.5, PM10, PM1.0, TVOC, temperature, humidity, ozone, alcohol, methane, ammonia, hydrogen sulfide, sulfur dioxide, and more. All gas detection is done using independent sensor probes. The types of gases detected can be freely selected for matching. With its compact design, small footprint, comprehensive functionality, stable performance, and high cost-effectiveness, it supports output modes such as RS485 serial port, 4G, Bluetooth, WIFI, etc., greatly facilitating the development and application of air quality detection and IoT gas detection solutions.
Air Quality Monitor FS00802C Features
1.Multi gas sensor in one, according customers’ detail requiments
We will produce the multi-in-one air quality monitor according to what gases need to be detected, each gas will be matched independent professional gas sensor.
2.Mutiple gas sensors are available to choose.
pm2.5, pm10, formaldehyde, CO2, TVOC, temperature and humidity, methane, ozone, illumination, ammonia, hydrogen sulfide, sulfur dioxide, nitrogen dioxide, sulfur hexafluoride, oxygen.
3.Multiple output methods are available to choose
FS00802C supports RS485, 4G, bluetooth, WIFI, Analog signal, Lora output methods.
4.Detects different types of gases and can be freely configured to meet the needs of different customers and scenarios.
Application
1.Internet of things equipment, air quality detection
2.Smart Building, Smart Community
3.Schools, hospitals, supermarkets, subways and other public places
4.Agricultural production, animal husbandry
5.Industrial workshops, production parks, etc.
Specifications
Parameter | Technical Specifications | |
Operation Voltage | DC 10V~30V (Standard 24V) | |
Operation Current | ≤200mA | |
Stable Time | 2min | |
Detection Frequency | Data is updated once per second (default) | |
Output Methods | Default | Modbus-RS485 |
Optional | Analog sginal、4G、WIFI、Bluetooth、Lora | |
Product Material | ABS Flame-retardant shell | |
Install Methods | Ceiling Mounted、Wall Mounted | |
Reference Size | 150x150x34 mm | |
Operation Temperature | -10℃~50℃ | |
Operation Humidity | 0~95%RH (Non-Condensation) | |
Storage Temperature | -20℃~60℃ | |
Storage Humidity | 0~99%RH (Non-Condensation) |
Type | Detection Gas | Detection Range | Solutions | Accuracy | Lifetime |
(MAX Error) | (in the air) | ||||
Regular Gas | Temperature | -40℃~100℃ | 0.01℃ | ≤ ±0.3℃ | 10Years |
Humidity | 0~99%RH | 0.1%RH | ≤ ±3%RH | 10Years | |
pm2.5 1.0 10 | 0~1000μg/m³ | 1μg/m³ | ≤ ±10% reading | ≥40000hours | |
CO2 | 400~5000ppm | 1ppm | ≤ ±(50ppm+3%reading) | 10Years | |
HCHO | 0~1500μg/m³ | 1μg/m³ | ≤ ±10%reading | 2Years | |
TVOC | 0~5000μg/m³ | 1μg/m³ | ≤ ±10%reading | 10Years | |
Non-gas | Illuminance | 0~65535Lux | 1Lux | ≤ ±7% @25℃ | 3Years |
Noise | 30db~130db | 0.1db | ≤ ±1db | 3Years | |
Air pressure | 30~110Kpa | 0.1Kpa | ≤ ±0.15Kpa | 3Years | |
Presence of human body | 0 or 1 | 1 | ≤ ±2% | 3Years | |
Special Gases | Alcohol | 0~500ppm | 1ppm | ≤ ±10%Reading | 2Years |
O3 | 0~10ppm | 0.001ppm | ≤ ±2%Reading | 2Years | |
CH4 | 0~100%LEL | 1%LEL | ≤ ±5%Reading | 2Years | |
CO | 0~1000ppm | 0.1ppm | ≤ ±3%Reading | 3Years | |
O2 | 0~25%Vol | 0.1%Vol | ≤ ±3%Reading | 2Years | |
NH3 | 0~20ppm | 1ppm | ≤ ±5%Reading | 1Year | |
H2S | 0~100ppm | 1ppm | ≤ ±5%Reading | 2Years | |
CL2 | 0~10ppm | 0.1ppm | ≤ ±3%Reading | 1Year | |
CLO2 | 0~20ppm | 0.1ppm | ≤ ±3%Reading | 2Years | |
SO2 | 0~20ppm | 0.1ppm | ≤ ±3%Reading | 2Years | |
H2 | 0~1000ppm | 1ppm | ≤ ±3%Reading | 1Year |