Electrochemical O2 Oxygen Gas Sensor Module FS01501
- O2 gas detection sensor module
- Support UART and MODBUS-RS485
- Three-electrode electro-chemical sensor
- Outstanding anti-interference
- Temperature compensation
- Reliable service for sustainable cooperation
Electrochemical O2 Oxygen Gas Sensor Module FS01501 Introduction
FS01501 is a fuel cell type electrochemical sensor that works by the oxidation and reduction reactions on the working electrode and counter electrode, releasing charges to form a current. The magnitude of the current generated is proportional to the concentration of oxygen and follows Faraday’s law. By testing the magnitude of the current, the oxygen concentration can be determined. It uses a high-stability gas sensor and a high-performance microprocessor that supports UART output and Modbus-RS485 output for easy use. The module adopts precise automatic calibration and detection equipment, reducing human interference and ensuring the accuracy and consistency of data during large-scale production.
Electrochemical O2 Oxygen Gas Sensor Module FS01501 Features
1.Detection range
Default: 0~25%Vol
Customizable: 30%-100%
2.High accuracy, high consistency, high solution, rapid response
Data detection accuracy MAX error: ≤0.5%Vol
Minimum solution: 0.1%Vol
Response time: T90 ≤10s
3.Data output methods
FS02001 supports UART and MODBUS-RS485;
Customizable: 4~20mA、0~5V、0~10V
4.Long service life
The lifetime is up to 2 years (in the air)
5.High detection frequency
The data updates once per second by default.
Application
1.Gas detectors, instrumentation equipment
2.Ventilators, medical and health equipment
3.Safety monitoring of industrial mines, tunnels, etc.
4.Farms, Smart Agriculture and Animal Husbandry
Specifications
Parameter type | Parameter index | |
Detection Type | O2 Gas | |
Detection Principle | Three-electrode electro-chemical | |
Detection Range | Default: 0~25%Vol | |
Customizable: 30%-100% | ||
Detection Accuracy | Solution | 0.1%Vol |
Data Accuracy | Max error:≤0.5%Vol | |
Operation Voltage | DC 3.7V~5.5V | |
Operation Current | <10mA (@5V power supply) | |
Response Time | T90 ≤60s | |
Warm-up Time | 3 min | |
Detection Frequency | The data is updated once per second (Default) | |
Output Methods | Default: UART (3.3V_TTL Voltage level) | |
Reserve: MODBUS-RS485 | ||
Customizable: 4~20mA、0~5V、0~10V | ||
Service Life | 2 Years (in the air) | |
Reference Dimension | 32.3×32.3×16.5 mm | |
Operation Temperature | -10℃ ~ 50℃ | |
Operation Humidity | 0~95%RH (Non-Condensation) | |
Storage Temperature | -20℃~60℃ | |
Storage Humidity | 0~99%RH (Non-Condensation) | |
Pressure Range | 800~1200 mbar |