Electrochemical H2S Hydrogen Sulfide Gas Sensor FS01700
H2S detection sensor
Support UART and MODBUS-RS485
Three-electrode electro-chemical sensor
Outstanding anti-interference
Temperature compensation
Reliable service for sustainable cooperation
Detection range: 0~10PPM
Data detection accuracy: ±≤5% reading
Minimum solution: 0.1 ppm
Response time: T90 ≤30s
OEM H2S gas sensor possible
Electrochemical H2S Hydrogen Sulfide Gas Sensor FS01700 Introduction
Electrochemical H2S gas sensor is a fuel cell type electrochemical sensor that works by the oxidation and reduction reactions on the working electrode and counter electrode, releasing charges to form a current. The magnitude of the current generated is proportional to the concentration of hydrogen sulfide and follows Faraday’s law. By testing the magnitude of the current, the hydrogen sulfide concentration can be determined. It uses a high-stability gas sensor and a high-performance microprocessor that supports UART output and Modbus-RS485 output for easy use. The module adopts precise automatic calibration and detection equipment, reducing human interference and ensuring the accuracy and consistency of data during large-scale production. People can use electrochemical hydrogen sulfide sensor in many applications, such as factory, enviromental monitor, industry instruments, industry production and so on.
Electrochemical H2S Gas Sensor Features
1.Detection range:Default: 0~10PPM
2.High accuracy, high consistency, high solution, rapid response :
Data detection accuracy: ±≤5% reading
Minimum solution: 0.1 ppm
Response time: T90 ≤30s
3.Data output methods:FS01700 supports UART and MODBUS-RS485
4.Long service life:The lifetime is up to 2 years (in the air)
5.High detection frequency: The data updates once per second by default.
H2S sensor Application
1.Gas detectors, instrumentation equipment
2.Ventilators, medical and health equipment
3.Safety monitoring of industrial mines, tunnels, etc.
4.Farms, Smart Agriculture and Animal Husbandry
Electrochemical H2S Gas Sensor Specifications
Parameter type | Parameter index | |
Detection Type | H2S Gas | |
Detection Principle | Three-electrode electro-chemical | |
Detection Range |
0~10PPM
| |
Max Load | 500PPM | |
Detection Accuracy | Solution | 0.1ppm |
Data Accuracy | Max error ≤2% Reading | |
Operation Voltage | DC 3.7V~5.5V | |
Operation Current | ≤0.3mA (@5V power supply) | |
Warm-up Time | 3 min | |
Detection Frequency | The data is updated once per second (Default) | |
Output Methods | Default: UART (3.3V_TTL Voltage level) | |
Reserve: MODBUS-RS485 | ||
Customizable: 4~20mA、0~5V、0~10V | ||
Service Life | 2 Years (in the air) | |
Reference Dimension | 32.3×32.3×16.5 mm | |
Operation Temperature | -10℃~ 50℃ | |
Operation Humidity | 0~95%RH (Non-Condensation) | |
Storage Temperature | -20℃~ 60℃ | |
Storage Humidity | 0~95%RH (Non-Condensation) | |
Pressure Range | 800~1200 mbar |