Product banner

Electrochemical H2S Hydrogen Sulfide Gas Sensor Module FS01701

  • H2S detection sensor module
  • Support UART and MODBUS-RS485
  • Three-electrode electro-chemical sensor
  • Outstanding anti-interference
  • Temperature compensation
  • Reliable service for sustainable cooperation

Electrochemical H2S Hydrogen Sulfide Gas Sensor Module FS01701 Introduction

FS01701 is a fuel cell type electrochemical sensor that works by the oxidation and reduction reactions on the working electrode and counter electrode, releasing charges to form a current. The magnitude of the current generated is proportional to the concentration of hydrogen sulfide and follows Faraday’s law. By testing the magnitude of the current, the hydrogen sulfide concentration can be determined. It uses a high-stability gas sensor and a high-performance microprocessor that supports UART output and Modbus-RS485 output for easy use. The module adopts precise automatic calibration and detection equipment, reducing human interference and ensuring the accuracy and consistency of data during large-scale production.

Electrochemical H2S Hydrogen Sulfide Gas Sensor Module FS01701 Features

1.Detection range

Default: 0~10PPM

 

2.High accuracy, high consistency, high solution, rapid response

Data detection accuracy: ±≤5% reading

Minimum solution: 0.1 ppm

Response time: T90 ≤30s

 

3.Data output methods

FS01701 supports UART and MODBUS-RS485

 

4.Long service life

The lifetime is up to 2 years (in the air)

 

5.High detection frequency

The data updates once per second by default.

Application

1.Gas detectors, instrumentation equipment
2.Ventilators, medical and health equipment
3.Safety monitoring of industrial mines, tunnels, etc.
4.Farms, Smart Agriculture and Animal Husbandry

Specifications

Parameter type Parameter index
Detection Type H2S Gas
Detection Principle Three-electrode electro-chemical
Detection Range 0~10PPM
Max Load 500PPM
Detection Accuracy Solution 0.1ppm
Data Accuracy Max error ≤2% Reading
Operation Voltage DC 3.7V~5.5V
Operation Current ≤0.3mA (@5V power supply)
Warm-up Time 3 min
Detection Frequency The data is updated once per second (Default)
Output Methods  Default: UART (3.3V_TTL Voltage level)
Reserve: MODBUS-RS485
Customizable: 4~20mA、0~5V、0~10V
Service Life 2 Years (in the air)
Reference Dimension 32.3×32.3×16.5 mm
Operation Temperature -10℃~ 50℃
Operation Humidity 0~95%RH (Non-Condensation)
Storage Temperature -20℃~ 60℃
Storage Humidity 0~95%RH (Non-Condensation)
Pressure Range 800~1200 mbar

Related Products​

email
whatsapp