Semiconductor C2H5OH Alcohol/Ethanol/ Methanol Sensor/Probe FS00700C
- Low cost and small size
- Simple application circuits
- High consistency
- Long service life
Semiconductor C2H5OH Alcohol Sensor FS00700C Introduction
Alcohol concentration sensor FS00700C is a type of semiconductor ethanol probe that utilizes precise automated production and testing equipment to reduce interference from human factors, ensuring good accuracy and consistency of data even in mass production. This methanol probe is particularly suitable for portable product applications due to its small size and ease of integration into various designs.
Work Principle Of Alcohol Level Sensor
The gas-sensitive material used in the gas sensor is a semiconductor material with low conductivity in clean air, with a built-in heating wire and metal electrode. When alcohol vapor exists in the sensor’s environment, the sensor’s conductivity will increase. And the change in conductivity increases with the concentration of alcohol gas. So ethanol gas sensor can sense the alcohol concentration in the air through the change in conductivity.
Semiconductor C2H5OH Alcohol Probe Features
1. Small and easy to integrate design
2. Data is precise and has good consistency
3. Low power consumption and long service life
4. High sensitivity to low-concentration pollutant gases
Specifications Of Ethanol Probe
Electrical parameters | Technical indicators | ||
Package standard | Metal package | ||
Detecting gas | Alcohol | ||
Detection range | 25~500ppm(Alcohol) | ||
Standard circuit | Circuit voltage | VC | ≤6V DC |
Heating voltage | VH | 0.9V±0.1V ACorDC | |
Load resistance | RL | Adjustable | |
Element characteristics under standard test conditions | Heating resistance | RH | 4Ω±0.5Ω(at room temperature) |
Heating power | PH | ≤140mW | |
Sensitive body resistance | Rs | 1KΩ-400KΩ(in air) | |
Sensitivity | S | Rs(in air)/Rs(in 125ppm Alcohol)≥3 | |
Concentration slope | α | ≤0.6(R300ppm/R50ppm Alcohol) | |
Standard test conditions | Temperature, humidity | 20℃±2℃;55%±5%RH | |
Preheating time | Not less than 48 hours | ||
Standard test circuit | VC:3.0V±0.1V | ||
VH:0.9V±0.1V |
How to Design Ethanol Probe By Fosensor Company
Application Of Ethanol Probe
1.Instrumentation, Alcohol tester
2.Air quality tester and module
3.Portable Alcohol Detector, Gas Analyzer
4.Air purifier etc.