Product banner

Battery Thermal Runaway Monitoring Sensor FS02208

  • High accuracy and repeatability
  • Fast response time

Battery Thermal Runaway Monitoring Sensor FS02208 Introduction

FS02208 is a battery thermal runaway monitoring sensor that can provide an external interface and continuously measure CO2, CO, HC, H2, while automatically compensating for temperature and pressure. It has a modular design and provides both digital and analog signal output functions, making it easy to integrate and control.

Battery Thermal Runaway Monitoring Sensor FS02208 Features

This can achieve an external interface and automatically complete temperature and pressure compensation while measuring CO2, CO, HC, H2 continuously.

 

Short start-up time and preheating time.

 

Modular design with both digital and analog signal output functions, which is easy to integrate and control.

 

High accuracy and repeatability, fast response time, up to 170ms.

Application

1.New energy vehicles, trams
2.Energy storage power station, power system
3.Battery Safety Monitoring Equipment

Specifications

Detection principles

CO2:Dual Beam NDIR

CO/HC/H2:MOX

PM dust: optical scattering principle 

Pressure:Piezoresistive

Temperature: NTC

Detection parameters

CO2、CO/HC/H2、PM、temperature, pressure 

Detection ranges

CO2: 0ppm-10000ppm

CO/HC/H2:1-1000ppm

PM:0-5mg/m³

Air Pressure:80kPa~120kPa

Temperature:-40℃~125℃

Resolution

CO2/CO/HC/H2:1ppm

PM:1ug/m³

Air Pressure:0.1kPa

Temperature:0.1℃

Detection accuracy

CO2: ±(50ppm+5% of reading)

 

CO/HC/H2: ±40ppm or ±30% of reading (whichever is greater)

 

PM: ≤100μg/m³: ±15μg/m³; >100μg/m³: ±15% of reading

 

Pressure P: ±0.1kPa

 

Temperature T: ±2℃

Data refresh rate

≤1s

Response time

T90<15s

Output mode

CAN/LIN/UART

Operating conditions

-40℃~+85℃, 0~99%RH (non-condensing).

Storage conditions

-40℃~+95℃, 0~99%RH (non-condensing).

Operating pressure

80kPa~120kPa

Power supply voltage

9~16VDC, with standard voltage at +12VDC.

Average working current

Normal operating mode: ≤150mA, @+12VDC (PM measurement intermittent operation)

 

Low power mode: ≤50mA, @+12VDC (CO2 sensor intermittent operation, PM and MOX sensor trigger operation, Temperature T and Pressure P normal operation)

Static current

<100uA in sleep mode

Related Products​

email
whatsapp